Skip to main content Skip to search Skip to main navigation

Regulatory Requirements for the Validation of Analytical Methods – Part 2

7 min. reading time | by Joachim Ermer
Published in LOGFILE 04/2025

Analytical methods are used throughout the development, manufacture and release of pharmaceutical substances and dosage forms. The accuracy and reliability of analytical results are therefore essential. Successful method validation proves that the test procedure is suitable for the defined application. In our last feature, we reported on the regulatory requirements for analytical method validation. Today, you can find out which aspects need to be considered when putting them into practice.

The full article, along with many other interesting topics, will soon be available on the GMP Compliance Adviser, the world's most comprehensive online GMP knowledge portal.


Important aspects in the implementation of regulatory requirements

The ICH guideline contains general requirements and some recommendations for basic statistical performance parameters and experimental approaches. However, this should not be understood or misused as a checklist. The responsibility of the user to adapt to the task is explicitly pointed out: "It is the responsibility of the applicant to choose the validation procedure and protocol most suitable for their product". Validation that is not tailored to the specific test procedure and its intended use is, at the very least, a waste of time and resources, as the suitability cannot be reliably assessed.

What does "suitable" method validation entail?

In particular, the aim of validation, i.e. proof of the suitability of the test method in routine use, must always be kept in mind. As far as possible, the routine conditions should be reflected in the experimental validation studies, for example by using samples of representative composition for testing the accuracy and lower limit of the working range, or by use of authentic samples in precision studies. Only then does the sample preparation, which often makes a significant contribution to precision, correspond to that used in batch release testing. If the routine conditions cannot be realized for experimental reasons, at least the possible influence on the assessment should be considered. Consideration of these "regular test conditions" is explicitly referred to in revision 2 of the validation guideline.

The user must identify the critical performance parameters for the test method and its use, determine these parameters experimentally in a reasonable and effective way and define sufficient acceptance criteria to confirm suitability.

Due to the iterative nature of test method development and validation, a rational design of the test procedure is the first prerequisite for optimal validation. A comprehensive understanding of the test procedure is a key objective of the new ICH Q14 guideline "Analytical Procedure Development", with a systematic quality-by-design approach (valid from June 2024).


Definition of acceptance criteria

To be able to assess whether a test method is suitable for the intended application, acceptance criteria must be defined. The definition of acceptance criteria was supplemented in Revision 2 of the validation guideline, but there is often a lack of guidance for derivation of the criteria. The correct requirement in the draft guideline (phase 2) that the precision must be compatible with the specification limits was removed in the final version of the guideline.

The acceptance limits of the specification represent the requirements for the respective quality attribute. For example, ICH guideline Q3A defines a required reporting limit for unknown impurities of 0.05 % or 0.03 %, depending on the daily dose of the respective active substance (≤ or > 2 g). Consequently, the test method must be able to quantify unknown impurities at this concentration, i.e. the reporting limit represents the maximum limit of quantitation.

The maximum permissible analytical variability for determinations of content is defined by the specification limits. Other performance parameters are method-specific and depend, for example, on the type of calibration, or on the experimental validation approach, but the random variability always represents the minimum contribution that must be considered.

Statistical significance tests check only for statistical significance, such as when using the mean value t-test of the difference between two mean values, which directly represents an acceptance criterion. Whether such a statistically significant difference has any practical significance is not the subject of the test.

Two scenarios can be distinguished here:

  • Producer risk: On the one hand, very low variability or a large amount of data can quickly lead to statistical significance. In this case, we speak of a producer risk, i.e. a test method that is acceptable in itself that does not meet the acceptance criteria. By simply increasing the amount of data, any difference – no matter how small – will eventually become significant.
  • Consumer risk: On the other hand, excessive variability can also mask practically significant differences, i.e. these are not tested as significant. In this case, one speaks of a consumer risk, i.e. poor performance is not detected, which can lead to the release of batches that do not conform to specifications.

This problem with significance tests is also pointed out in the USP general chapter on the validation of compendial methods <1225>: "Setting an acceptance criterion based on the lack of statistical significance ... is not an acceptable approach."

Statistical equivalence tests are recommended in ICH Q2(R2) for precision and accuracy: "The observed ... 100(1-α) % confidence interval (or justified alternative statistical ... interval should be compatible with the corresponding accuracy acceptance criteria". Here the question is – correctly stated – not whether the observed difference is statistically significant, but whether this difference (including its confidence interval as a measure of uncertainty) lies within a previously defined acceptance range. The latter introduces a measure of practical relevance. As confidence intervals become smaller with increasing numbers of data points and decreasing levels of variability, the probability of a positive test result increases, in contrast to the significance tests. This procedure is also described in the general USP information chapter <1010> as well in specialist literature and allows a (numerically) validated risk control via the α-error which is used. The inclusion of uncertainty (compared to a simple comparison of the calculated parameters with the acceptance criteria) requires either wider acceptance limits or a larger number of values to reduce the confidence intervals.

Unfortunately, no context is discussed in ICH Q2(R2), i.e. whether equivalence testing is expected in all cases. In the author's opinion, the comparison approach should be chosen depending on the risk of the quality attribute and the test procedure (complexity). If the risk is low, a simple comparison is perfectly acceptable.


Acceptance limits for precision

As the final result is compared with the specification limits (USP <General Notices>), its precision is decisive in determining the suitability of the test method. The specified limits for precision must include at least the manufacturing and analytical variability. The manufacturing variability can be estimated for a manufacturing technology type based on experience or determined by determining a larger number of batches in a measurement series using analysis of variance. The minimum requirement for the precision of the final result can be derived from the remaining available range, for example from the probabilities of the normal distribution. An acceptable probability to be within or outside (OOS) the specification limits serves as a measure of suitability.

For liquid chromatographic methods of content determination for active substances, there are specifications for the precision of injection in Ph.Eur. and USP. These depend on the number of injections and the difference between the upper specification limit of the active substance monograph and the theoretical upper limit of the true content 100 %, i.e. the available range for analytical variability. To ensure the same uncertainty, the acceptable precision decreases with decreasing number of injections. The random spread of standard deviations depends on the number of values (chi-squared distribution), but a general factor of 2 can be assumed between the true standard deviation and the upper limit of the distribution. The acceptance limit of 0.85 % for the injection precision from 6 injections and a 102 % upper specification limit would therefore be realistic up to a true RSD of about 0.4 %, but with 3 injections the true RSD must not exceed 0.2 %.

When quantifying impurities or other trace analytes, the strong concentration dependence of the precision must be taken into account. The reporting limit can be used here as a uniform reference concentration to ensure that the requirements are met, as a repeatability or intermediate precision of 25 % or 30 % allows acceptable quantification.


Do you have any questions or suggestions? Please contact us at: redaktion@gmp-verlag.de

Dr. Joachim Ermer
Dr. Joachim Ermer

You may also be interested in the following articles:

How is a QRM process initiated?

How is a QRM process initiated?

You can view the answer here:
Read more
FDA: Updated Pre-RFD Guidance for Combination Products

FDA: Updated Pre-RFD Guidance for Combination Products

The U.S. FDA has released an updated final guidance on preparing a Pre-Request for Designation (Pre-RFD), replacing the previous 2018 version. The revised document provides new recommendations for interacting with the Office of Combination Products (OCP) and clarifies expectations for Pre-RFD submissions.
Read more
EDQM: 9 Virtual Training Modules on Ph. Eur. and CEPs

EDQM: 9 Virtual Training Modules on Ph. Eur. and CEPs

The EDQM has introduced a modular training programme covering chemically defined active substances and medicinal products. It will take place between 1 and 12 December 2025.
Read more
Previous
Next

Related Products

Skip product gallery
GMP Compliance Adviser | Named User Licence | 12M

GMP Compliance Adviser | Named User Licence | 12M

The GMP Compliance Adviser is an online publication that covers all aspects of Good Manufacturing Practice (GMP) in one source.In the GMP Compliance Adviser you’ll find: GMP in Practice This part contains 21 chapters with GMP expert knowledge to base your decisions upon. It provides practical assistance with checklists, templates and SOP examples. It is written by more than 80 authors with hands-on experience directly linked to the industry. The individual chapters describe the different aspects of GMP in clear language. Technical, organizational and procedural aspects are covered.More than 700 checklists, templates and examples of standard operation procedures taken directly out of practice help you in understanding the GMP requirements.GMP RegulationsThese chapters cover the most important GMP regulations from Europe and the United States (CFR and FDA), but also PIC/S, ICH, WHO and many more.  Sample Documents In addition, the GMP Compliance Adviser contains many sample documents and practical examples that you can use.

Ready for dispatch, Delivery time appr. 2-5 workdays (2-3 weeks for christmas goodies)
€1,335.00 net excl. VAT
GMP:KnowHow Pharma Logistics (GDP) | Named User License | 12M

GMP:KnowHow Pharma Logistics (GDP) | Named User License | 12M

Your knowledge base about GDP-compliant handling of your pharmaceutical logistics. It is important that you as a logistics service provider, but also as a client in the pharmaceutical industry, adhere precisely to the regulatory requirements. The GMP:KnowHow knowledge portal guides you through the regulatory jungle of the pharmaceutical and logistical supply chain! The knowledge portal gives you an easy-to-understand overview of all the important topics. Using graphics, you can easily navigate through all the areas covered by the EU GDP Guidelines (2013/C 343/01). You also have the relevant passages of the regulations directly at hand for each topic. This allows you to compare the requirements directly and saves you a lot of time on time-consuming searches and research!One thing is certain: the knowledge portal answers your questions about the supply chain of medicinal products, active pharmaceutical ingredients and medical devices. You don't have to be an expert. Yet.You will find answers to your questions in the GMP:KnowHow Pharma Logistics (GDP). Where does GDP begin, where does GMP end? What does GDP-compliant mean? When do I also have to take GMP requirements into account? What permits do I need for certain activities? What requirements do I have to fulfil? What is the current legal basis? How am I covered? What authorizations do I have for my work, e.g. from my employer? Who is responsible — the client or the contractor? And many more What is the difference to the GMP Compliance Adviser? The GMP:KnowHow Pharma Logistics (GDP) is your guideline for Good Distribution Practice. It is a product that is independent of the GMP Compliance Adviser and concentrates on content that is essential for carriers of medicinal products, active pharmaceutical ingredients and medical devices as well as for logistics clients. The focus is on practical knowledge and how to apply it in your daily business. If necessary, the relevant regulations can be called up immediately alongside the practical knowledge, and you can see the relevant paragraphs at a glance. In addition, sample documents are available to help you make immediate progress. AuthorSimone Ferrante – now Director Quality at Fisher Clinical Services – was previously Head of Quality Control and Responsible Person according to GDP (VP) for the entire Grieshaber Group. She is also a long-standing author and GDP expert at GMP-Verlag.

Ready for dispatch, Delivery time appr. 2-5 workdays (2-3 weeks for christmas goodies)
€610.00 net excl. VAT
E-Learning GMP:READY | GMP for Engineers Online Course

E-Learning GMP:READY | GMP for Engineers Online Course

Why are GMP rules important for technicians and engineers? Technicians and engineers play a key role in ensuring compliance with Good Manufacturing Practice (GMP) standards. They are involved in critical activities such as: planning and construction of ventilation systems, maintenance of water treatment plants, calibration of measuring sensors. Therefore, they are jointly responsible for the quality of medicines and must ensure that their work complies with GMP standards.Your advantages: Fast familiarization with GMP topics in approx. 2 hours, time- and location-independent online training, printable personal certificate, 12-month access for initial and follow-up training, automatic updates in case of legal changes, content compliant with Article 7(4) of Directive 2003/94/EC.

Ready for dispatch, Delivery time appr. 2-5 workdays (2-3 weeks for christmas goodies)
€240.00 net excl. VAT
GMP Fundamentals | A Step-by-Step Guide

GMP Fundamentals | A Step-by-Step Guide

This handbook is a practical and easy to read guideline, giving you a quick and comprehensive overview of the complex world of Good Manufacturing Practice (GMP) without the need of previously acquired knowledge. Some topics are: GMP: Purpose and basic pharmaceutical terms Laws, licenses and inspections Personnel: Responsibility and hygiene Standard Operating Procedures (SOP) and documentation Design of rooms and facilities Processing and packaging Quality control and market release Suppliers, storage and logistics (Good Distribution Practice = GDP) Alphabetical index and abbreviations Using practical examples and comparisons to every-day life will help to easy understand GMP regulations.GMP Fundamentals is a helpful guide which facilitates the entry into the GMP world and teaches the necessary basics.

Ready for dispatch, delivery immediately after receipt of payment
€44.90 net excl. VAT