Are there any requirements regarding the microbiological monitoring of sewage drains in production rooms?

Microbiological Monitoring of Sewage Drains

There are no direct specifications for the inspection within the framework of microbiological monitoring, but it is expected to be carried out based on risk. This involves evaluating the sources of contamination in terms of their potential impact.

Checking the drains may be useful to verify the effectiveness of the disinfection process. In the outer area (on the room side on the floor above the closures), this could be considered as a potential "worst case" by sampling the surface. In this case, frequency and limit values depend on the risk of the processed dosage form and thus the cleanroom class (monitoring programme).

An inspection inside the drainage system can certainly be carried out with the aim of checking the effectiveness of the disinfection step. This also raises the question of the limit value that would have to be set for this. If the drain construction is not suitable due to design or damage (closability, backflow, ventilation, disinfectability), this should be corrected if possible. Open drains should be avoided per se. Otherwise, this risk point would have to be taken into account in the monitoring, accordingly.

Summary

Floor areas are in any case rather rarely the subject of monitoring due to their indirect potential influence. The risk assessment for determining the monitoring programme should take this into account. Examination of the inner sides of (closed) drains is normally not necessary. However, it can be helpful for root cause investigation in the context of investigations of OOS results on batches or in the case of deviating/abnormal monitoring results.